DocumentCode :
504848
Title :
Deliberation of fluorescent material by used in low temperature measurement
Author :
Miyazaki, Y. ; Watabiki, M. ; Sindo, T. ; Aizawa, H. ; Katsumata, T. ; Komuro, S.
Author_Institution :
Sensor Photonics Res. Center, Toyo Univ., Saitama, Japan
fYear :
2009
fDate :
18-21 Aug. 2009
Firstpage :
5596
Lastpage :
5599
Abstract :
A possibility of low temperature measurement using fluorescence material was examined. Temperature dependence of fluorescence lifetime applied to low temperature measurement. Inorganic fluorescence material is known as a suitable sensor material for temperature measurement. Ruby was used as a sensor material because of bright fluorescence and long fluorescence lifetime. Fluorescence thermometer using the ruby which is modified for temperature measurement has been fabricated. From this research, ruby crystal is found to be useful as the sensor head for fluorescence thermometer. In addition, the ruby crystal is potentially useful material for the sensor head crystals to measure low temperature below 273 K.
Keywords :
fluorescence; low-temperature techniques; radiative lifetimes; ruby; spectral methods of temperature measurement; thermometers; Al2O3:Cr; fluorescence lifetime; fluorescence thermometer; inorganic fluorescent material; low-temperature measurement; ruby crystal; sensor material fabrication; Chemical sensors; Crystalline materials; Crystals; Fluorescence; Magnetic field measurement; Magnetic heads; Temperature dependence; Temperature measurement; Temperature sensors; Thermal sensors; fluorescence; low temperature; optical fiber; ruby; thermometer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
ICCAS-SICE, 2009
Conference_Location :
Fukuoka
Print_ISBN :
978-4-907764-34-0
Electronic_ISBN :
978-4-907764-33-3
Type :
conf
Filename :
5334801
Link To Document :
بازگشت