DocumentCode :
512815
Title :
Research on the stability of IUR76-I/IUR76-II test systems for flame detectors and related national standards
Author :
Yang, Li ; Guo-Sheng, Zhang ; Li-Kun, Lu ; Chong, Zhao
Author_Institution :
Sch. of Inf. & Mech. Eng., Beijing Inst. of Graphic Commun., Beijing, China
Volume :
1
fYear :
2009
fDate :
5-6 Dec. 2009
Firstpage :
220
Lastpage :
222
Abstract :
The stability of test system for flame detectors is relied on the stabilities of critical optical devices, such as optical source, filter set, and optical modulator. To increase the stability of normal test system for flame detectors, IUR76-I/II test systems for flame detectors are self-designed and manufactured based on the related national standards of P.R.C. Being different with traditional test systems, the new optical source is equipped in IUR76-I/II test systems. Comprehending the stability of main optical devices, the different of system stability between new test system and the requirements of national standards are calculated and researched in this paper. And the suggestions for the related national standards also are mentioned.
Keywords :
infrared detectors; light sources; stability; test equipment; IUR76-I test system; IUR76-II test system; filter set; flame detectors; national standards; optical modulator; optical source; test system stability; Automatic testing; Fires; Infrared detectors; Manufacturing; Optical devices; Optical filters; Optical modulation; Petroleum; Stability; System testing; flame detector; infrared; stability; test system; ultraviolet;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Test and Measurement, 2009. ICTM '09. International Conference on
Conference_Location :
Hong Kong
Print_ISBN :
978-1-4244-4699-5
Type :
conf
DOI :
10.1109/ICTM.2009.5412955
Filename :
5412955
Link To Document :