• DocumentCode
    513601
  • Title

    Transient electric field distribution within the working volume of an NEMP simulator

  • Author

    Thomas, M. Joy ; Sunitha, K.

  • Author_Institution
    Dept. of High Voltage Eng., Indian Inst. of Sci., Bangalore, India
  • fYear
    2006
  • fDate
    23-24 Feb. 2006
  • Firstpage
    396
  • Lastpage
    401
  • Abstract
    Nuclear electro-magnetic pulse (NEMP) simulators which are used in the simulation of transient electromagnetic fields due to a high altitude nuclear detonation are generally excited with a double exponential high voltage pulse. This results in a current distribution on the wires of the simulator and hence a transient electric field in the working volume of the simulator where the test object is kept. It is found that for the simulator under study, the current distribution is non-uniform and so is the field distribution along the width of the simulator in the working volume. To make the current distribution uniform, several methods have been suggested and the results of these methods are analyzed and suitable conclusions are arrived at from those results.
  • Keywords
    current distribution; electric fields; electromagnetic pulse; current distribution; high altitude nuclear detonation; nuclear electromagnetic pulse simulators; transient electric field distribution; Circuit testing; Current distribution; EMP radiation effects; Earth; Electromagnetic fields; Electromagnetic transients; Surges; System testing; Voltage; Wires;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    ElectroMagnetic Interference and Compatibility (INCEMIC), 2006 Proceedings of the 9th International Conference on
  • Conference_Location
    Bangalore
  • Print_ISBN
    978-1-4244-5203-3
  • Type

    conf

  • Filename