DocumentCode :
520276
Title :
Forward and 90-degree light scattering measurements in optofluidic flow cytometer
Author :
Godin, Jessica ; Lo, Yu-Hwa
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of California at San Diego, La Jolla, CA, USA
fYear :
2010
fDate :
16-21 May 2010
Firstpage :
1
Lastpage :
2
Abstract :
A microfluidic flow cytometer for three-parameter light scatter measurements is demonstrated to distinguish between 4 sizes of polystyrene beads from 5-15 ∝ m. Light blocking and guiding elements are employed in this compact, integrated microfluidic chip.
Keywords :
integrated optoelectronics; light scattering; micro-optics; microfluidics; polymers; guiding elements; integrated microfluidic chip; light blocking; light scattering measurements; microfluidic flow cytometer; optofluidic flow cytometer; polystyrene beads; three parameter light scatter measurements; Cells (biology); Fluid flow measurement; Light scattering; Lighting; Microfluidics; Mie scattering; Optical scattering; Optical waveguides; Scattering parameters; Size measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Lasers and Electro-Optics (CLEO) and Quantum Electronics and Laser Science Conference (QELS), 2010 Conference on
Conference_Location :
San Jose, CA
Print_ISBN :
978-1-55752-890-2
Electronic_ISBN :
978-1-55752-890-2
Type :
conf
Filename :
5499845