• DocumentCode
    522410
  • Title

    Review of instruments and techniques for tropo spheric calibration in radio science experiments

  • Author

    Graziani, Alberto ; Martellucci, Antonio ; Tortora, Paolo

  • Author_Institution
    II Fac. di Ing., Univ. di Bologna, Forli, Italy
  • fYear
    2010
  • fDate
    12-16 April 2010
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Radio science experiments aimed to the estimation of general relativity parameters request very stringent requirements in terms of observables residual noise. Among the error sources affecting observable signals, transmission media represent a significant contribution. The frequency dependant transmission media is removed with the multifrequency link, while a dedicated ground based system is necessary for the troposphere calibration. In the framework of the Mercury Orbiter Radioscience Experiment (MORE) noise level requirements have been defined. The natural choice is the use of a microwave radiometer (MWR) capable to estimate the troposphere path delay with low noise level along the line of sight of the spacecraft. The undertaken activity has focused on the evaluation of the characteristics of a MWR developed at ESA in order to satisfy the MORE requirements.
  • Keywords
    calibration; geophysical techniques; radio links; radiometers; troposphere; Mercury orbiter radio science experiment; dedicated ground based system; frequency dependant transmission media; microwave radiometer; multifrequency link; noise level requirements; spacecraft; troposphere path delay; tropospheric calibration techniques; Atmospheric measurements; Calibration; Delay estimation; Geoscience; Instruments; Meteorology; Noise level; Stability; Terrestrial atmosphere; Variable speed drives;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas and Propagation (EuCAP), 2010 Proceedings of the Fourth European Conference on
  • Conference_Location
    Barcelona
  • Print_ISBN
    978-1-4244-6431-9
  • Electronic_ISBN
    978-84-7653-472-4
  • Type

    conf

  • Filename