DocumentCode :
524052
Title :
Impact of external influences on the ex equipment choice and technical answers from standards
Author :
Lefebvre, Xavier ; Toninelli, Maurizio ; Cottin, Olivier
Author_Institution :
TECHNOR AS, Stavanger, Norway
fYear :
2010
fDate :
15-17 June 2010
Firstpage :
1
Lastpage :
7
Abstract :
Ex electrical equipment intended to be used in explosive atmospheres shall be selected and/or installed so that it is protected against external influences which could adversely affect the explosion protection (e.g. pressure conditions, chemical, mechanical, vibratory, thermal, electrical, humidity, corrosion). External influences shall be identified as part of the installation design and selection of equipment for the installation and measures applied for control shall be documented and included in the explosion protection document. Petrochemical plants are often submitted to several heavy conditions due to external influences. We would like to highlight that Ex standards including installation and maintenance codes give complete or partial answers in order to guarantee the suitability of Ex equipment with these specific conditions.
Keywords :
explosion protection; maintenance engineering; petrochemicals; power apparatus; EX electrical equipment; Ex standards; explosion protection; maintenance codes; petrochemical plants; Atmosphere; Corrosion; Explosion protection; Explosives; Hazardous areas; IEC standards; Ignition; Page description languages; Safety devices; Standards publication; Ex equipment; external influences; installation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
PCIC Europe 2010 Conference Record
Conference_Location :
Oslo
ISSN :
2151-7665
Print_ISBN :
978-1-4244-6968-0
Electronic_ISBN :
2151-7665
Type :
conf
Filename :
5525735
Link To Document :