DocumentCode
526035
Title
In situ correction of abbe offset error in the watt balance experiment
Author
Haddad, D. ; Steiner, R. ; Williams, E. ; Liu, R.
Author_Institution
Nat. Inst. of Stand. & Technol. (NIST), Gaithersburg, MD, USA
fYear
2010
fDate
13-18 June 2010
Firstpage
14
Lastpage
15
Abstract
The paper describes a technique to simultaneously measure the tilt angles of the induction coil used in the watt balance experiment and correct its position from the Abbe offset error. The same three laser interferometers placed on the induction coil to determine the vertical position are also used for angular measures. An optimization algorithm is tested that allow a better estimation and correction of the Abbe offset error.
Keywords
error correction; light interferometers; optimisation; wattmeters; Abbe offset error correction; angular measures; in situ correction; induction coil; laser interferometers; optimization algorithm; tilt angles; watt balance experiment; Error correction; Goniometers; Interferometers; Magnetic field measurement; Magnetic flux; NIST; Optical interferometry; Position measurement; Superconducting coils; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location
Daejeon
Print_ISBN
978-1-4244-6795-2
Type
conf
DOI
10.1109/CPEM.2010.5544638
Filename
5544638