DocumentCode
527922
Title
Very high density microelectrode array with monolithically integrated readout circuits
Author
Hashemi, Sedigheh ; Joye, Neil ; Schmid, Alexandre ; Leblebici, Yusuf
Author_Institution
Commun. Circuits Lab., Univ. of California in Los Angeles, Los Angeles, CA, USA
fYear
2010
fDate
18-21 July 2010
Firstpage
1
Lastpage
4
Abstract
This paper presents the hardware realization and modeling of high-density microelectrode arrays including both microelectronic readout amplifiers as well as three-dimensional microelectrodes forming a fully integrated CMOS compatible system enabling research in electrophysiology. The presented chip offers the highest density of microprobes, reported in literature, all of which can be accessed through on-chip amplifiers, using a time-multiplexing scheme. An accurate model of the electrode interface including noise performance is also presented.
Keywords
CMOS integrated circuits; amplifiers; bioelectric phenomena; biomedical electrodes; microelectrodes; readout electronics; 3D microelectrode; CMOS compatible system; electrophysiology; high density microelectrode array; microelectronic readout amplifier; monolithically integrated readout circuit; noise performance; Arrays; CMOS integrated circuits; Integrated circuit modeling; Microelectrodes; Noise; Semiconductor device modeling;
fLanguage
English