• DocumentCode
    531117
  • Title

    Bio-radiolocation method at chest wall motion analysis during tidal breathing

  • Author

    Korchagina, D.A. ; Alekhin, M.D. ; Anishchenko, L.N.

  • Author_Institution
    Bauman Moscow State Tech. Univ., Moscow, Russia
  • fYear
    2010
  • fDate
    Sept. 30 2010-Oct. 1 2010
  • Firstpage
    475
  • Lastpage
    478
  • Abstract
    Influence of chest wall surface motion in bio-radar signal during tidal breathing was researched. A high-speed camera and multi-frequency radar with signal step modulation were simultaneously applied. The model of chest motion during quite breathing was used. Pairwise correlation coefficients for all the markers on the chest wall given in the model were calculated. The correlation of data from high-speed camera and bio-radar was found. Two methods were compared.
  • Keywords
    correlation methods; pneumodynamics; radar applications; bioradiolocation method; chest wall motion analysis; high-speed camera; multifrequency radar; pairwise correlation coefficients; signal step modulation; tidal breathing; Cameras; Correlation; Data processing; Humans; Modulation; Radar remote sensing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radar Conference (EuRAD), 2010 European
  • Conference_Location
    Paris
  • Print_ISBN
    978-1-4244-7234-5
  • Type

    conf

  • Filename
    5614951