• DocumentCode
    533395
  • Title

    ESD events of cabled GMR sensors

  • Author

    Iben, Icko Eric Timothy

  • Author_Institution
    Tape Head Dev. Group, IBM Corp., San Jose, CA, USA
  • fYear
    2010
  • fDate
    3-8 Oct. 2010
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    ESD damage from cable discharge events (CDEs) of magnetoresistive sensors is a major problem in manufacturing of magnetic tape and hard disk drives. CDEs initiated by contact to the cable pads used to connect to external electronics represent one source. This paper addresses CDEs from other points of contact, including capacitive coupling to metal objects contacting the cable. In order for capacitively coupled ESD events to damage the sensor the capacitive coupling of the two sensor leads to the external object being discharge must be different.
  • Keywords
    cables (electric); electrostatic discharge; magnetic sensors; magnetoresistive devices; CDE; cable discharge events; cable pads; cabled GMR sensors; capacitive coupling; coupled ESD events; hard disk drives; magnetic tape manufacturing; magnetoresistive sensors; Electrostatic discharge; Lead; Magnetic sensors; Power cables; Resistors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/ Electrostatic Discharge Symposium (EOS/ESD), 2010 32nd
  • Conference_Location
    Reno, NV
  • Print_ISBN
    978-1-58537-182-2
  • Electronic_ISBN
    978-1-58537-182-2
  • Type

    conf

  • Filename
    5623766