• DocumentCode
    533516
  • Title

    Variable hysteresis current control applied in a shunt active filter with constant switching frequency

  • Author

    Vahedi, Hani ; Sheikholeslami, Abdolreza

  • Author_Institution
    Department of Electrical Engineering, Babol University of Technology, Iran
  • fYear
    2010
  • fDate
    14-15 Sept. 2010
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Presence of harmonics in power networks makes it inevitable to use power filters. Shunt active power filters (APF) are widely used in power systems to eliminate the current harmonics and to compensate reactive power due to their accurate and fast operation. In this paper the instantaneous power theory is used to extract the harmonic components of system current. Then fixed-band hysteresis current control is explained. Because of fixed-band variable frequency disadvantages, the adaptive hysteresis current control (AHCC) is introduced that leads to fix the switching frequency and reduce the high frequency components in source current waveform. Some simulations are done in Matlab/Simulink. The Fourier Transform and THD results of source and load currents are discussed to prove the validity of this method.
  • Keywords
    Frequency control; Adaptive Hysteresis Current Control; Instantaneous Power Theory; Power System Harmonics; Shunt Active Power Filter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Quality Conference (PQC), 2010 First
  • Conference_Location
    Tehran, Iran
  • Print_ISBN
    978-1-4244-8483-6
  • Electronic_ISBN
    978-964-463-063-7
  • Type

    conf

  • Filename
    5624729