  • Abstract
    Methodical error calculations of the air ions concentration measuring instrument is carried out. The majority of the commercial air ionization counters produced in our country and abroad is for domestic use and is not able to monitor the degree of ionization, which makes it unsuitable for use in medical practice. The aims of this article are description of the structure of the counter of air ions, the calculation of its precision and accuracy compared to industrially produced counters.