• DocumentCode
    534553
  • Title

    Implementation of time reversal method (TRM) and its application to magnetoacoustic tomography (MAT)

  • Author

    Li, Xun ; Hu, Sanqing

  • Author_Institution
    Coll. of Comput. Sci., Hangzhou Dianzi Univ., Hangzhou, China
  • Volume
    1
  • fYear
    2010
  • fDate
    16-18 Oct. 2010
  • Firstpage
    319
  • Lastpage
    323
  • Abstract
    We introduce the logic process of the TRM derivation, and propose the assumptions for the implementation of the TRM. The numerical simulations are conducted with four sound sources models including one point source, two adjacent point sources, sources on a circle and sources on two closed curves, to evaluate the performance of TRM and its application to MAT. The results show that the TRM can precisely reconstruct the MAT sound source from the detected acoustic pressure.
  • Keywords
    acoustic tomography; biomedical ultrasonics; magnetoacoustic effects; medical image processing; numerical analysis; TRM derivation logic process; adjacent point sources; magnetoacoustic tomography; numerical simulations; time reversal method; Acoustics; Image reconstruction; Magnetic resonance imaging; Magnetoacoustic effects; Surface reconstruction; Tomography; Transmission line measurements; Magnetoacoustic Tomography; Medical Imaging; Time Reversal Method;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering and Informatics (BMEI), 2010 3rd International Conference on
  • Conference_Location
    Yantai
  • Print_ISBN
    978-1-4244-6495-1
  • Type

    conf

  • DOI
    10.1109/BMEI.2010.5639503
  • Filename
    5639503