  • Title

    The study of the change of pressure and its relationship with the temperature inside the cup

  • Author

    Ng, Shih-Chau ; Guo, Heng-Yan ; Sun, Jia ; Sun, Ping-Long

  • Author_Institution
    Acupuncture, Moxibustion & Tuina Collage, Shanghai Univ. of Traditional Chinese Med., Shanghai, China
  • Volume
    6
  • fYear
    2010
  • fDate
    16-18 Oct. 2010
  • Firstpage
    2507
  • Lastpage
    2510
  • Abstract
    Background: The cupping therapy is practiced widely in China. By observing the pressure and temperature changes inside the cup during the cupping therapy session, the relationship between these was studied to further the understanding of the therapeutic mechanism of cupping therapy. Methods: The research used a self-made 260ml glass cup equipped with both pressure and temperature probes that was applied to the lower back area (around BL23) of volunteers. The data of the tropical negative pressure and temperature change inside the glass cup was recorded during the 10 minutes cupping session using PowerLab data acquisition system. Results: The linear regression equation for both tropical negative pressure and temperature inside the cup during the 10-minute cupping session were Y = -0.13X-32.138, and the significant test for the regression coefficient was p ≥ 0.05, the high P value showed no statistically significant linear relationship between the tropical negative pressure and temperature inside the cup during the 10 minutes cupping session; in addition the correlation coefficient r = 0.04, and the coefficient of determination R2=0.002 also demonstrated that both variables had a weak linear relationship. Conclusion: The decrease in temperature was not the main factor for the changes of tropical negative pressure inside the cup during the cupping session. The main therapeutic mechanism of cupping was the mechanical stress created by the tropical negative pressure.
  • Keywords
    medicine; patient treatment; pressure; regression analysis; China; PowerLab data acquisition system; cupping therapy; linear regression equation; pressure change; temperature; therapeutic mechanism; Glass; Linear regression; Medical treatment; Probes; Sun; Temperature distribution; Cup; Pressure; Temperature; Tropical negative Pressure;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering and Informatics (BMEI), 2010 3rd International Conference on
  • Conference_Location
    Yantai
  • Print_ISBN
    978-1-4244-6495-1
  • Type

    conf

  • DOI
    10.1109/BMEI.2010.5639684
  • Filename
    5639684