• DocumentCode
    534803
  • Title

    Effect of fiducial configuration on target registration eerror in image-guided surgery-A experiment study

  • Author

    Zhang, Wenbin ; Shen, Guofang ; Wang, Chenhao ; Liu, Yuncai

  • Author_Institution
    Dept. of Oral & Maxillofacial Surg., Ninth People´´s Hosp., Shanghai, China
  • Volume
    4
  • fYear
    2010
  • fDate
    16-18 Oct. 2010
  • Firstpage
    1477
  • Lastpage
    1481
  • Abstract
    This paper investigates the effect of fiducials configuration on target registration error (TRE) and test the accuracy of theoretical model of TRE prediction in image-guided cranio-maxillofacial surgery. The skull specimen is prepared with 20 titanium microscrews placed at defined locations and scanned with a 64-slice spiral computed tomography unit. These markers are separated to registration fiducial group and target fiducial group. An optical tracking system is used to perform skull-to-image registration procedures. Subsequent to each registration, the TRE is calculated by the navigation system. Each configuration have been performed registration 50 times and the average is regarded as TRE of the configuration. The TRE prediction is also calculated for each configuration. The TRE ranges from 0.58mm to 3.88mm, relatively smaller values of TRE may be achieved by placing a majority of fiducials on the maxillary alveolus in proximity about the target and placing a small number on the cranium contralaterally. The TRE values are always larger than the corresponding TRE prediction but there is high correlation between them. The configuration of fiducials is an important factor in minimizing TRE and the TRE prediction is a good guidance for fiducial markers placement.
  • Keywords
    biomedical optical imaging; bone; brain; computerised tomography; image registration; medical image processing; surgery; cranium; fiducial configuration; image-guided craniomaxillofacial surgery; optical tracking system; skull; skull-to-image registration; spiral computed tomography; target registration error; Accuracy; Extraterrestrial measurements; Navigation; Neurosurgery; Orbits; Three dimensional displays; image-guided surgery; registration; target registration error;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Engineering and Informatics (BMEI), 2010 3rd International Conference on
  • Conference_Location
    Yantai
  • Print_ISBN
    978-1-4244-6495-1
  • Type

    conf

  • DOI
    10.1109/BMEI.2010.5640096
  • Filename