Thermal Calculation of a Buried Gas Pipeline
Author
Hu, Yanjiao
Author_Institution
Airport Coll., Civil Aviation Univ. of China, Tianjin, China
Volume
1
fYear
2010
fDate
12-14 Nov. 2010
Firstpage
111
Lastpage
113
Abstract
In a gas pipeline design, compressor station spacing is relative to gas temperature inside of a pipeline when design pressure of a gas pipeline is given. It is feasible to assume that gas temperature is unchanged in hydraulic calculation when gas temperature change along pipeline is relatively small. It is necessary to consider thermal calculation when the temperature change along pipeline is enough large. Combining with BWRS equation of state and hydrodynamic calculation formula, basic calculation formula of temperature drop along pipeline was deduced based on energy conservation law. Calculation steps of calculating length, average gas temperature and temperature distribution along pipeline were presented. As shown by example calculation and analysis, thermal calculation is very important to a gas pipeline design.
Keywords
compressors; design engineering; gas industry; hydrodynamics; pipelines; thermal analysis; buried gas pipeline; compressor station spacing; design pressure; energy conservation law; gas pipeline design; gas temperature change; hydraulic calculation; hydrodynamic calculation formula; temperature drop; thermal calculation; Equations; Heat transfer; Heating; Mathematical model; Pipelines; Soil; Temperature; calculation-section; gas pipeline; thermal calculation;
fLanguage
English
Publisher
ieee
Conference_Titel
System Science, Engineering Design and Manufacturing Informatization (ICSEM), 2010 International Conference on
Conference_Location
Yichang
Print_ISBN
978-1-4244-8664-9
Type
conf
DOI
10.1109/ICSEM.2010.36
Filename
5640157
Link To Document