Abstract
According to the automatic verification of float flowmeter problems, we put forward a device, and it can acquire float height. An MVC - II - 1MM camera is used to capture flowmeter images, and saves them in computer in the form of BMP files. By some functions, such as the edge detection, filtering, binary, expansion, refined, etc, and other algorithms programmed by specific characteristics the float position is detected. This measurement has a precision of 10% smallest calibration.
Keywords
edge detection; flow visualisation; flowmeters; BMP files; MVC II 1MM camera; automatic identification; edge detection; float flowmeter problems; float height; float position; flowmeter images; Calibration; Electron tubes; Glass; Image edge detection; Pixel; Rotors;