DocumentCode
537916
Title
Closeup and remote short circuit transient calculation model on DC traction power supply system with 24-pulse rectifier
Author
Zhang, JunLing ; Feng, Xiaoyun ; Li, Ke ; Zheng, Jun ; Huang, Dandan
Author_Institution
Dept. of Electr. Eng., Southwest Jiaotong Univ., Chengdu, China
fYear
2010
fDate
10-13 Oct. 2010
Firstpage
97
Lastpage
101
Abstract
DC traction power supply with 24-pulse rectifier is widely used in urban railway transit system. It is necessary to consider short circuit fault protection, because it is crucial for the design of equipments to meet requirements of safety and reliability. This paper presents a 24-pulse rectifier model, based on which the closeup and remote short circuit currents are obtained by programs. The calculation model presented is simple, efficient, and easy to get realized. The current profiles are then compared with that modeled in MATLAB/SIMULINK to prove their reliability. The result shows the accuracy of the model.
Keywords
railways; rectifiers; traction power supplies; DC traction power supply system; pulse rectifier; railway transit system; short circuit fault protection; short circuit transient calculation model; Admittance; Integrated circuit modeling; Mathematical model; Rectifiers; Short circuit currents; Substations; Traction power supplies; 24-pulse rectifier; DC traction power supply; Short circuit;