• DocumentCode
    539728
  • Title

    High Reliable Partial Discharge Online Monitoring System of Hydro-generator

  • Author

    Yuan, Wan ; Chuangli, Gong ; Zhipeng, Wei ; Pengcheng, Deng ; Li Yun

  • Author_Institution
    Wu-ling Electr. Power Corp., Changsha, China
  • Volume
    2
  • fYear
    2011
  • fDate
    6-7 Jan. 2011
  • Firstpage
    320
  • Lastpage
    323
  • Abstract
    Partial discharge (PD) online monitoring is considered as one of the most effective means to prevent sudden accidents of hydro-generator. In this paper, a set of high reliable hydro-generator PD online monitoring system was developed, which made use of PDA technique to obtain PD signal and adopted PD integrated monitoring method to make sure the credibility of PD analysis results. Three aspects of investigation were carried out to ensure the high reliability of the system: (a) to effectively eliminate the on-site interferences and ensure the reliability of PD pulses acquisition, the PDA method is adopted and pulse time-delay technique is studied;(b) to overcome the isolation properties of the traditional PD online monitoring and ensure the high reliability of PD analysis results, on the base of the PD influence factors analysis, the PD integrated monitoring and association analysis model was set up, (c) to verify the reliability of the installation of PD sensors, the security performance of PD sensor body during hydro-generator in short circuit fault was studied. At present, the system has been applied to several hydro-generators in a huge-size hydropower plant.
  • Keywords
    electric sensing devices; fault diagnosis; hydroelectric generators; partial discharges; power generation reliability; PD sensor body; PD signal; PDA technique; association analysis model; high reliability partial discharge online monitoring system; hydrogenerator; hydropower plant; influence factors analysis; pulse time-delay technique; pulses acquisition; short circuit fault; Insulation; Monitoring; Partial discharges; Reliability; Sensors; Stator windings; High reliability; Hydro-generator; Integrated monitoring and association analysis model; Online monitoring; Partial discharge (PD);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Measuring Technology and Mechatronics Automation (ICMTMA), 2011 Third International Conference on
  • Conference_Location
    Shangshai
  • Print_ISBN
    978-1-4244-9010-3
  • Type

    conf

  • DOI
    10.1109/ICMTMA.2011.367
  • Filename
    5721185