• DocumentCode
    541663
  • Title

    Three-dimensional analysis of septal curvature from cardiac magnetic resonance images for the evaluation of severity of pulmonary hypertension

  • Author

    Maffessanti, F. ; Sciancalepore, M.A. ; Patel, A.R. ; Gomberg-Maitland, M. ; Chandra, S. ; Caiani, E.G. ; Freed, B.H. ; Lang, R.M. ; Mor-Avi, V.

  • Author_Institution
    Univ. of Chicago, Chicago, IL, USA
  • fYear
    2010
  • fDate
    26-29 Sept. 2010
  • Firstpage
    801
  • Lastpage
    804
  • Abstract
    Although abnormal motion of the interventricular septum (IVS) caused by elevated right ventricular pressure in patients with pulmonary hypertension (PH) is easy to recognize visually, determination of the severity of PH relies on measurements of pulmonary arterial pressure (PAP). We hypothesized that quantitative 3D analysis of regional IVS curvature throughout the cardiac cycle could be used to differentiate patients with different degrees of PH. Cardiac magnetic resonance (CMR) images (Philips 1.5T) were obtained in 14 normal subjects and 30 patients with PH undergoing right heart catheterization, who were divided into 3 subgroups according to mean PAP. Images were used to reconstruct dynamic 3D LV endocardial surfaces, which were analyzed to calculate 3D IVS curvature throughout the cardiac cycle. In normal subjects, IVS curvature was positive, reflecting the convex septal shape and showed little change throughout the cardiac cycle. In patients with PH, IVS curvature was lower, reflecting septal flattening, and fluctuated throughout the cardiac cycle, reflecting the abnormal “bouncing” septal motion. In patients with severe PH, IVS curvature reached negative values, reflecting transient concave septal shape. Dynamic 3D analysis of IVS curvature from CMR images may provide an alternative for noninvasive assessment of severity of PH.
  • Keywords
    biomedical MRI; blood pressure measurement; blood vessels; catheters; image motion analysis; image reconstruction; medical image processing; abnormal motion; bouncing septal motion; cardiac cycle; cardiac magnetic resonance images; convex septal shape; dynamic 3D analysis; elevated right ventricular pressure; endocardial surfaces; image reconstruction; interventricular septum; noninvasive assessment; pulmonary arterial pressure measurement; pulmonary hypertension severity; right heart catheterization; septal curvature; septal flattening; three-dimensional analysis; transient concave septal shape; Blood pressure; Hypertension; Image reconstruction; Imaging; Shape; Surface reconstruction; Three dimensional displays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology, 2010
  • Conference_Location
    Belfast
  • ISSN
    0276-6547
  • Print_ISBN
    978-1-4244-7318-2
  • Type

    conf

  • Filename
    5738094