DocumentCode
54196
Title
Radiated Immunity in Reverberation and Semianechoic Rooms: Conditions for Equivalence
Author
Tsigros, C. ; Piette, Marc ; Vandenbosch, Guy A. E. ; Van Troyen, D.
Author_Institution
Lab. of Electro Magn. Applic., R. Mil. Acad., Brussels, Belgium
Volume
55
Issue
2
fYear
2013
fDate
Apr-13
Firstpage
222
Lastpage
230
Abstract
General recommendations are given concerning the equivalence of radiated immunity testing results obtained experimentally in a semianechoic room (SAR) and a reverberation chamber (RC). The relation between the parameters influencing the results, i.e., the number of aspect angles in an SAR and the number of tuner steps in an RC has been inventoried in an extensive experimental campaign and is discussed in detail. To that purpose, an innovating canonical equipment under test), designed as a common reference equipment for standardized testing in both environments, has been constructed. The RC was equipped with two different and innovative tuning systems.
Keywords
immunity testing; reverberation chambers; RC; SAR; aspect angles; common reference equipment; innovating canonical equipment under test; innovative tuning systems; radiated immunity; radiated immunity testing equivalence; reverberation chamber; reverberation rooms; semianechoic rooms; standardized testing; Antennas; Rails; Resonant frequency; Standards; Testing; Tuners; Canonical equipment under test (CEUT); component; radiated immunity testing; reverberation chamber (RC); semianechoic room (SAR);
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/TEMC.2012.2219869
Filename
6328263
Link To Document