• DocumentCode
    54412
  • Title

    Evaluation of ITER TF Coil Joint Performance

  • Author

    Kajitani, Hideki ; Hemmi, Tsutomu ; Mizutani, Takumi ; Matsui, Kunihiro ; Yamane, Minoru ; Obana, Tetsuhiro ; Takada, Suguru ; Hamaguchi, Shinji ; Takahata, Kazuya ; Imagawa, Shinsaku ; Koizumi, Norikiyo

  • Author_Institution
    Japan Atomic Energy Agency (JAEA), Naka, Japan
  • Volume
    25
  • Issue
    3
  • fYear
    2015
  • fDate
    Jun-15
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    To evaluate the ITER TF joint performance, the joint test sample, which consists of two short TF conductors and has full size joint, shall be tested using NIFS test facility under the condition of current of 68 kA and external field of 2 T. For high accuracy, the issue of voltage difference between cable and jacket had been anticipated in the evaluation of joint resistance. If a voltage difference exist between them, it is difficult to measure real joint resistance using voltage taps on the jacket. Therefore, the author first calculated the position where voltage of cable and jacket become equipotential and then decided the voltage tap position where the influence of voltage drop could be avoided. Thus, a high accuracy measurement of joint resistance could be achieved and the joint resistance was accurately evaluated as around 1 nΩ, which is well below the ITER requirement of 3 nΩ.
  • Keywords
    coils; ITER TF coil joint performance evaluation; NIFS test facility; TF conductors; current 68 kA; joint resistance; voltage tap position; Cable shielding; Coils; Conductors; Electrical resistance measurement; Joints; Resistance; Voltage measurement; ITER TF coil; TF conductor; joint resistance;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2014.2365543
  • Filename
    6965582