DocumentCode :
544742
Title :
Order estimation and model verification in autoregressive modeling of EEG sleep recordings
Author :
Aufrichtig, Richard ; Pedersen, Simon Boel
Author_Institution :
Electronics Institute, The Technical University of Denmark, DK 2800, Denmark
Volume :
6
fYear :
1992
fDate :
Oct. 29 1992-Nov. 1 1992
Firstpage :
2653
Lastpage :
2654
Abstract :
Use of autoregressive modeling in biomedical signals is widespread. This paper discusses problems associated with finding an optimal model for a signal. Model order criteria and model verification by statistical testing is addressed. The methods are applied on EEG recordings from different sleep stages. It is shown that 5 second EEG segments can be described efficiently by an AR(14) model.
Keywords :
Adaptation model; Analytical models; Biological system modeling; Brain modeling; Electroencephalography; Manuals; Welding;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE
Conference_Location :
Paris, France
Print_ISBN :
0-7803-0785-2
Electronic_ISBN :
0-7803-0816-6
Type :
conf
DOI :
10.1109/IEMBS.1992.5761495
Filename :
5761495
Link To Document :