DocumentCode
544905
Title
Fading characteristics of a 2.3 GHz hospital radio telemetry channel
Author
Wang, Li-Quan ; Evans, Noel E. ; Burns, J. Brian ; Matthews, John G W
Author_Institution
Dept. of Electr. & Electron. Eng., Univ. of Ulster at Jordanstown, UK
Volume
3
fYear
1992
fDate
Oct. 29 1992-Nov. 1 1992
Firstpage
1232
Lastpage
1233
Abstract
An upper UHF band for hospital radio telemetry use has been evaluated. Signal strength measurements show good agreement with the Rayleigh distribution over non-LOS paths. The channel can accommodate wideband data transmission and provide an adequate output signal-to-noise ratio with a +10 dBm source.
Keywords
Rayleigh channels; biomedical telemetry; data communication; medical computing; medical information systems; Rayleigh distribution; adequate output signal-noise ratio; fading characteristics; frequency 2.3 GHz; hospital radio telemetry channel; nonLOS paths; signal strength use measurements; upper UHF band; wideband data transmission; Antennas; UHF measurements;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 1992 14th Annual International Conference of the IEEE
Conference_Location
Paris
Print_ISBN
0-7803-0785-2
Electronic_ISBN
0-7803-0816-6
Type
conf
DOI
10.1109/IEMBS.1992.5761760