• DocumentCode
    546686
  • Title

    Study of a confocal configuration for imaging cameras working at 220 GHz

  • Author

    Maestrojuán, I. ; Gonzalo, R. ; Ederra, I. ; Teniente, J.

  • Author_Institution
    Antennae Group, Public Univ. of Navarra, Pamplona, Spain
  • fYear
    2011
  • fDate
    11-15 April 2011
  • Firstpage
    445
  • Lastpage
    447
  • Abstract
    Terahertz technology for developing imaging cameras is of interest nowadays. That is the reason why different configurations for an imaging camera are studied in this paper. This research is focused on a confocal configuration and different kinds of parameters will be changed in order to get a compromise between them. All the study has been done with the commercial software package GRASP.
  • Keywords
    cameras; terahertz wave imaging; GRASP software package; confocal configuration; frequency 220 GHz; imaging cameras; terahertz technology; Cameras; Feeds; Mirrors; Shape;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Antennas and Propagation (EUCAP), Proceedings of the 5th European Conference on
  • Conference_Location
    Rome
  • Print_ISBN
    978-1-4577-0250-1
  • Type

    conf

  • Filename
    5782461