• DocumentCode
    546843
  • Title

    Preliminary comparative results on axial resolution using both coded excitation and conventional pulses in ultrasound A-mode scan

  • Author

    Machado, T.M. ; Costa, E.T.

  • Author_Institution
    Dept. of Biomed. Eng., Univ. of Campinas, Campinas, Brazil
  • fYear
    2011
  • fDate
    March 28 2011-April 1 2011
  • Firstpage
    439
  • Lastpage
    444
  • Abstract
    This paper presents a comparative study of axial resolution of ultrasound system with waves generated by coded excitation pulse and conventional pulses both interacting with computational phantoms producing A-line and B-mode images. The mathematical phantoms were generated as two impulse reflectors positioned at 10 mm (first reflector) and at 10.9 mm (second reflector). The second reflector was moved towards the first reflector in 0.1 mm steps. Reflectors were in the farfield of a 5 MHz transducer and waves are travelling in water. The transducer was excited with conventional short pulse (CP) and with coded excitation pulse (CEP). CEP was achieved with chirps with 18 μs duration. The combinations of transducer excitation (CP and CEP) with conventional and matched (MF) and mismatched filters (MMF) were tested and our results have shown that the system resolution was around 0.5 mm and that the combination CEP+MMF presented worse resolution and speckle effects when compared to other combinations probably due to the broadening of the mainlobe caused by this kind of operation.
  • Keywords
    biomedical transducers; biomedical ultrasonics; image resolution; mathematical analysis; medical image processing; optical elements; phantoms; ultrasonic imaging; ultrasonic transducers; A-line image; B-mode images; axial resolution; coded excitation; computational phantoms; conventional pulses; distance 10 mm; distance 10.9 mm; frequency 5 MHz; impulse reflectors; matched filters; mathematical phantoms; mismatched filters; preliminary comparative results; speckle effects; time 18 mus; transducer; ultrasound A-mode scan; water travelling waves; Chirp; Matched filters; Phantoms; Signal resolution; Speckle; Transducers; Ultrasonic imaging; chirp excitation; matched and mismatched filters; speckle; ultrasound;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Health Care Exchanges (PAHCE), 2011 Pan American
  • Conference_Location
    Rio de Janeiro
  • Print_ISBN
    978-1-61284-915-7
  • Type

    conf

  • DOI
    10.1109/PAHCE.2011.5871915
  • Filename
    5871915