DocumentCode
54994
Title
Using Ex nA Motors Safely: Myths About Prestart Purging, Ventilation, and Pressurization in Zone 2 Motors
Author
Mistry, Bharat ; Hombourger, Gerard ; Massey, Evans
Author_Institution
Technol.-Large Motors & Generators, GE Ind. & Consumer, Peterborough, ON, Canada
Volume
20
Issue
6
fYear
2014
fDate
Nov.-Dec. 2014
Firstpage
45
Lastpage
51
Abstract
The authors discuss the importance of such features in Ex nA motors with respect to the present and most up-todate International Electrotechnical Commission (IEC) 60079-15 [9] standard of Ex nA motors. At the same time, various applications, associated risks, and the proper selection of this expensive large motor feature are discussed.The different aspects of design and application are considered, comparing the North American and IEC standards in terms of safety to identify a clear selection of such features. Ultimately, this article provides guidance for those who are considering implementing this expensive design when they could seemingly select and apply the right Ex nA motors for the right application and location without such features.
Keywords
IEC standards; electric motors; ventilation; Ex nA motor safety; IEC 60079-15 [9] standard; International Electrotechnical Commission 60079-15 [9] standard; North American standards; large-motor application; large-motor feature selection; large-motor risks; pressurization; prestart purging; ventilation; zone 2 motors; Compressors; Electric motors; Explosives; Ignition; Induction motors; Ventilation; Voltage measurement;
fLanguage
English
Journal_Title
Industry Applications Magazine, IEEE