DocumentCode :
550413
Title :
Measuring range extension of turbine flowmeter using data processing method
Author :
Li Gang ; Li Qiao-Zhen ; Zhang Hai-peng
Author_Institution :
Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China
fYear :
2011
fDate :
22-24 July 2011
Firstpage :
3044
Lastpage :
3046
Abstract :
The turbine flowmeter is widely used to measure gas or liquid flow, because of these advantages of high accuracy, excellent repeatability and low pressure drop. However, the character of non-linearity limits the extension of its measuring range. A new method of measuring range extension is presented in this paper, through the analysis of the pulse signal outputted by the tubine sensor. This method is simple and practicable, which can also be used in other sensors with pulse signal output.
Keywords :
computerised instrumentation; data analysis; flow measurement; flow sensors; flowmeters; mechanical engineering computing; turbines; data processing method; gas flow measurement; liquid flow measurement; measuring range extension; nonlinearity; pressure drop; pulse signal output; tubine sensor; turbine flowmeter; Electric variables measurement; Electrical engineering; Electronic mail; Fluid flow measurement; Pressure measurement; Pulse measurements; Turbines; Measuring range extension; Pulse signal; Turbine flowmeter;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Control Conference (CCC), 2011 30th Chinese
Conference_Location :
Yantai
ISSN :
1934-1768
Print_ISBN :
978-1-4577-0677-6
Electronic_ISBN :
1934-1768
Type :
conf
Filename :
6000751
Link To Document :
بازگشت