Abstract :
This paper deals with the analysis and implementation of a low cost calorimetric setup, suitable for loss measurements in power electronic converters, for power ratings up to 30W. Main component of the device is an open Dewar vessel. A proper calibration method is suggested and the several error factors are spotted, so as to achieve an overall accuracy of 2%. Application examples are demonstrated with loss measurements on magnetic components.
Keywords :
calibration; calorimetry; loss measurement; power convertors; calorimetric setup; loss measurement; magnetic components; open Dewar vessel; power 30 W; power electronic converters; Calibration; Fasteners; Loss measurement; Temperature distribution; Temperature measurement; Thermistors; Voltage measurement; Measurement; efficiency; magnetic component; sensor; user application experience;