Title :
Efficiency measurements on active du/dt output filtering
Author :
Tyster, Juho ; Strom, Juha-P. ; Korhonen, Jari ; Silventoinen, Pertti
Author_Institution :
Lappeenranta Univ. of Technol., Lappeenranta, Finland
fDate :
Aug. 30 2011-Sept. 1 2011
Abstract :
Active du/dt filtering method can reduce the size of filter component physical size, and achieve superior filtering results. This enables very low overvoltage with long motor cables. The losses and power dissipation associated with the method is addressed. A comparison with passive filters is introduced, and silicon carbide components evaluated. The use of silicon carbide free-wheeling diodes results in significant loss reduction at least in 5.5 kW-22 kW motor power levels. The power dissipation of the inverter is measured with a temperature rise/thermal resistance method, and the results compared with chamber calorimeter results.
Keywords :
active filters; invertors; power cables; power system measurement; active filter; efficiency measurements; free-wheeling diodes; inverter; losses; motor cables; power dissipation; silicon carbide; temperature rise method; thermal resistance method; Filtering; Inverters; Loss measurement; Passive filters; Power measurement; Temperature measurement; Voltage control; Active filter; Silicon carbide; Variable speed drive;
Conference_Titel :
Power Electronics and Applications (EPE 2011), Proceedings of the 2011-14th European Conference on
Conference_Location :
Birmingham
Print_ISBN :
978-1-61284-167-0
Electronic_ISBN :
978-90-75815-15-3