DocumentCode
553901
Title
Numerical calculation of q and d axis reactance for permanent magnet generator based on coupled field
Author
Wen Jiabin ; Ren Yanping
Author_Institution
Coll. of Electr. & Electron. Eng., Harbin Univ. of Sci. & Technol., Harbin, China
Volume
1
fYear
2011
fDate
22-24 Aug. 2011
Firstpage
537
Lastpage
540
Abstract
Accurate calculation of the armature reaction reactance parameters has a great impact on the performance of the generator, but the existing methods are difficult to consider the interactive influence of the d axis and q axis. So the calculation is not more accurate. In this paper, reactance parameters were calculated by modifying the relative permeability. The obtained data were very close to the experimental value. This method was proved to be accurate. On the basis of the method, the changes of reactance parameters were also analyzed with mechanical angle and armature current variation. In addition, this paper summarized the influence of length of magnetization direction, air gap and power factor on reactance parameters, which had great significance to improve the performance of the generator.
Keywords
numerical analysis; permanent magnet generators; permeability; D axis reactance; Q axis reactance; air gap; armature current variation; armature reaction reactance parameters; coupled field; magnetization direction length; mechanical angle variation; numerical calculation; permanent magnet generator; power factor; relative permeability modification; Earth; Magnetic analysis; Materials; Saturation magnetization; Permanent magnet generator; finite element method; reactance parameters;
fLanguage
English
Publisher
ieee
Conference_Titel
Strategic Technology (IFOST), 2011 6th International Forum on
Conference_Location
Harbin, Heilongjiang
Print_ISBN
978-1-4577-0398-0
Type
conf
DOI
10.1109/IFOST.2011.6021081
Filename
6021081
Link To Document