• DocumentCode
    555487
  • Title

    Challenges in the scaling of energy savings baselines on mine compressed air systems

  • Author

    Marais, JH ; Kleingeld, M. ; Van Rensburg, JF

  • Author_Institution
    North-West Univ., Potchefstroom, South Africa
  • fYear
    2011
  • fDate
    16-17 Aug. 2011
  • Firstpage
    88
  • Lastpage
    92
  • Abstract
    Several Demand Side Management (DSM) projects have been implemented on mine compressed air systems at South African mines. The Measurement and Verification (M&V) of the achieved energy savings is important in assessing and evaluating the success of the projects. External factors beyond the scope of the DSM projects influence the energy consumption of mine compressed air systems. This complicates the measurement and verification process. A method that involves the deactivation of newly installed energy saving control systems for a short period after implementation is suggested where other scaling methods is not a suitable option.
  • Keywords
    compressed air systems; demand side management; energy measurement; mining; DSM project; South African mines; achieved energy saving M&V; demand side management; energy consumption; energy saving baselines; energy saving control systems; measurement-and-verification process; mine compressed air systems; scaling methods; Electricity; Energy measurement; Gold; Integrated circuits; Manganese;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial and Commercial Use of Energy (ICUE), 2011 Proceedings of the 8th Conference on the
  • Conference_Location
    Cape Town
  • Print_ISBN
    978-1-4577-1745-1
  • Electronic_ISBN
    978-0-9814311-6-1
  • Type

    conf

  • Filename
    6033089