DocumentCode
555492
Title
Various procedures to reduce a mine´s compressed air usage
Author
Schutte, AJ ; Kleingeld, M. ; Vosloo, J.
Author_Institution
North West Univ., Potchefstroom, South Africa
fYear
2011
fDate
16-17 Aug. 2011
Firstpage
116
Lastpage
123
Abstract
This article focuses on the results from the various procedures employed to reduce a mine´s compressed air usage and consequently the electrical energy consumption. The case studies are from DSM projects investigated and implemented on mine compressed air systems.
Keywords
compressed air systems; demand side management; energy conservation; energy consumption; mining; DSM project; daily cost saving; electrical energy consumption; energy efficiency; mine compressed air system; peak reduction; Compressors; Frequency modulation; Manganese; Switches;