  • Abstract
    Electronic systems in composite structures could be vulnerable to the (dominant magnetic) field caused by a lightning strike, because only thin layers of metal can be used on composite structures. Thin layers result in a very low shielding effectiveness against magnetic fields. Many experiments using large 10/350μs lightning current impulses have been carried out nearby several structures to investigate the effect of field coupling.
  • Keywords
    composite materials; electromagnetic pulse; lightning protection; metals; shielding; composite structures; electromagnetic pulse; electronic systems; lightning; magnetic fields; shielding; thin metal layers; Aluminum; Copper; Electromagnetic compatibility; Lightning; Magnetic fields; Radar; 10/350µs lightning pulse; shielding effectiveness; skin effect;