  • Title

    Calculation method of production log holdup using CAT instrument

  • Author

    Song, Wen Guang

  • Author_Institution
    Coll. of Comput. Sci., Yangtze Univ., Jingzhou, China
  • fYear
    2012
  • fDate
    21-24 Feb. 2012
  • Firstpage
    445
  • Lastpage
    446
  • Abstract
    This paper researches a set of interpretation for capacitance array tool (CAT) production logging data interpretation. It devises the water-holding rate of the CAT data and verified that this method can produce the horizontal well logging data interpretation. So it has some research value.
  • Keywords
    capacitive sensors; flow measurement; flow sensors; pipe flow; well logging; CAT instrument; capacitance array tool; production log well; production logging data interpretation; water holding rate; Instruments; Moisture; Phase measurement; Production; Sensors; Sun; Capacitance Array Tool; Production Log Well; Water-Holding Rate;