DocumentCode :
563762
Title :
Static and dynamic high-voltage pulse transformers
Author :
Novac, B.M. ; Smith, I.R. ; Goh, S E ; Senior, P. ; Stewardson, H.R.
Author_Institution :
Department of Electronic and Electrical Engineering, Loughborough University, Leicestershire, LE11 3TU, UK
fYear :
2000
fDate :
20-25 June 2000
Firstpage :
313
Lastpage :
316
Abstract :
The Marx generator is commonly used when it is required to produce high-voltage pulses on a high impedance load. There are however applications in which this will be either too costly or not useful for remote applications and the present paper describes two novel techniques to overcoming these difficulties. Theoretical and experimental results show that high-voltage pulses with rise times of a few tens of nanoseconds can be generated using these techniques.
Keywords :
Capacitance; Density measurement; Energy measurement; Generators; Instruments; high voltage; magnetic flux-compression; pulse transformers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
High-Power Particle Beams, 2000 13th International Conference on
Conference_Location :
Nagaoka, Japan
Type :
conf
Filename :
6220172
Link To Document :