DocumentCode
563936
Title
Diagnostic techniques for the 12 MeV linear induction accelerator
Author
Li Qin ; Guangsen, Dai ; He Guorong ; Ma Bing ; Deng Jianjun ; Jin-Shui, Shi
Author_Institution
Inst. of Fluid Phys., CAEP, Mianyang, China
fYear
2004
fDate
18-23 July 2004
Firstpage
589
Lastpage
592
Abstract
The 12MeV linear induction accelerator (12 MeV LIA) consists of an injector and 32 accelerating cells assembled in eight blocks, and a focus section leading electron beam to the high Z metal target to produce intense bremsstrahlung X-ray pulse. This paper describes the diagnostic techniques used in 12MeV LIA. In total there are approximately 41 beam diagnostic channels and 60 pulse power signals which are recorded on the oscilloscope, a subsystem of time interval measurement between the accelerator triggering and the X-ray producing which can measure and adjust the time of X-ray producing, a X-ray spot size measurement device. The results from several measurements and the data analysis are presented.
Keywords
X-ray production; bremsstrahlung; linear accelerators; particle beam diagnostics; 12 MeV linear induction accelerator; X-ray producing; X-ray spot size measurement device; accelerating cells; accelerator triggering; beam diagnostic channels; data analysis; diagnostic techniques; electron beam; electron volt energy 12 MeV; high Z metal target; injector; intense bremsstrahlung X-ray pulse; oscilloscope; pulse power signals; time interval measurement; Area measurement; Handheld computers; Linear particle accelerator;
fLanguage
English
Publisher
ieee
Conference_Titel
High-Power Particle Beams (BEAMS 2004), 2004 International Conference on
Conference_Location
St. Petersburg
Print_ISBN
978-5-87911-088-3
Type
conf
Filename
6220615