Title :
Goodness-of-fit tests in radiated susceptibility tests
Author :
Monsef, Florian ; Cozza, Andrea
Author_Institution :
Lab. des Signaux et Syst., Univ. Paris-Sud SUPELEC, Gif-sur-Yvette, France
Abstract :
Goodness-of-fit (GoF) tests are commonly used to assess the degree of perfection of a reverberation chamber to fulfill the overmoded condition. One may expect the outcome of GoF tests to provide some hints on the value of practical interest. The present paper shows that no correlation is found between the outcome of GoF tests and the range of values taken by the maximum power which is of practical interest in radiated susceptibility tests.
Keywords :
reverberation chambers; statistical testing; GoF tests; goodness-of-fit tests; overmoded condition; radiated susceptibility tests; reverberation chamber; Correlation; Exponential distribution; Frequency measurement; Probes; Reverberation chamber; Standards;
Conference_Titel :
Aerospace EMC, 2012 Proceedings ESA Workshop on
Conference_Location :
Venice
Print_ISBN :
978-1-4673-0302-6