DocumentCode
564556
Title
Goodness-of-fit tests in radiated susceptibility tests
Author
Monsef, Florian ; Cozza, Andrea
Author_Institution
Lab. des Signaux et Syst., Univ. Paris-Sud SUPELEC, Gif-sur-Yvette, France
fYear
2012
fDate
21-23 May 2012
Firstpage
1
Lastpage
5
Abstract
Goodness-of-fit (GoF) tests are commonly used to assess the degree of perfection of a reverberation chamber to fulfill the overmoded condition. One may expect the outcome of GoF tests to provide some hints on the value of practical interest. The present paper shows that no correlation is found between the outcome of GoF tests and the range of values taken by the maximum power which is of practical interest in radiated susceptibility tests.
Keywords
reverberation chambers; statistical testing; GoF tests; goodness-of-fit tests; overmoded condition; radiated susceptibility tests; reverberation chamber; Correlation; Exponential distribution; Frequency measurement; Probes; Reverberation chamber; Standards;