• DocumentCode
    564556
  • Title

    Goodness-of-fit tests in radiated susceptibility tests

  • Author

    Monsef, Florian ; Cozza, Andrea

  • Author_Institution
    Lab. des Signaux et Syst., Univ. Paris-Sud SUPELEC, Gif-sur-Yvette, France
  • fYear
    2012
  • fDate
    21-23 May 2012
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Goodness-of-fit (GoF) tests are commonly used to assess the degree of perfection of a reverberation chamber to fulfill the overmoded condition. One may expect the outcome of GoF tests to provide some hints on the value of practical interest. The present paper shows that no correlation is found between the outcome of GoF tests and the range of values taken by the maximum power which is of practical interest in radiated susceptibility tests.
  • Keywords
    reverberation chambers; statistical testing; GoF tests; goodness-of-fit tests; overmoded condition; radiated susceptibility tests; reverberation chamber; Correlation; Exponential distribution; Frequency measurement; Probes; Reverberation chamber; Standards;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Aerospace EMC, 2012 Proceedings ESA Workshop on
  • Conference_Location
    Venice
  • Print_ISBN
    978-1-4673-0302-6
  • Type

    conf

  • Filename
    6232513