Abstract :
Due to a wrong wiring of the solar panels on a Double Star spacecraft, very large magnetic interferences (20-30 nT) occurred in the magnetic field vector measurements. Furthermore, the shunting system of the spacecraft solar power system caused sudden changes in the level of interferences. Finally the observations suffered from frequent telemetry errors causing random spikes in the data. With help of dual fluxgate measurements and signal processing technique, the data have been cleaned first from the spikes and then from the solar array disturbances to an accuracy of better than 0.5 nT for most of the time. This paper presents the basic steps of the cleaning procedures.
Keywords :
aerospace instrumentation; cleaning; magnetic field measurement; solar cells; space vehicle power plants; space vehicles; cleaning procedures; dc magnetic field measurements; double star spacecraft; dual fluxgate technique; magnetic field vector measurements; solar panels; strong solar array disturbances; telemetry errors; very large magnetic interferences; Arrays; Cleaning; Magnetic field measurement; Magnetic fields; Sensors; Space vehicles; Telemetry;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Aerospace EMC, 2012 Proceedings ESA Workshop on
Conference_Location :
Venice
Print_ISBN :
978-1-4673-0302-6
Type :
conf
Filename :
6232550
Link To Document :
بازگشت