DocumentCode
567842
Title
The diagnostic value of two echocardiography methods for atrial septal aneurysm
Author
Zhang, Xiaomei ; Sun, Jinghui ; Wang, Zhaoxia ; Yuan, Xiaofeng ; Zhang, Li
Author_Institution
Dept. of Pediatrics, First Hosp. of Jilin Univ., Changchun, China
Volume
1
fYear
2012
fDate
3-5 Aug. 2012
Firstpage
476
Lastpage
479
Abstract
To evaluate the diagnostic value and clinical significance of two echocardiography methods in detecting atrial septal aneurysm (ASA). 44 cases of ASA with normal carotid arteries were retrospectively analyzed. Characteristic of ASA was detected by Transthoracic echocdrdiography (TTE) and Transesophageal echocordioqraphy (TEE), including the width of basal part, maximal excursion or protrusion beyond the plane of the atrial septum, direction of protrusion, motion, thickness of wall, presence of thrombi attaching to the wall, atrial septal defect, outflow tract obstruction and other structural abnormalities associated with ASA. It was founded that ASA occurred in the oval fossa, and the vast majority of ASA stretch to the right atrium. 4 cases were complicated by atrial septal defect and 6 cases were patent foramen ovale. No significant differences were found with two methods in bulging height, width, and wall thickness of ASA between children, adolescent and adult. ASA´s TEE diagnostic accuracy of 92.6%, while only 54.5% of TTE. The results suggest that two methods have reliable diagnostic value to ASA, can find with or without complications and provide valuable information for clinical diagnosis and treatment. TEE is more helpful to characterize different types of ASA and superior to TTE in the diagnostic accuracy to ASA.
Keywords
blood vessels; echocardiography; medical disorders; TEE diagnostic accuracy; atrial septal aneurysm; atrial septal defect; atrial septum; carotid artery; diagnostic value; outflow tract obstruction; patent foramen ovale; protrusion direction; structural abnormalities; transesophageal echocordioqraphy; transthoracic echocdrdiography; wall motion; wall thickness; Accuracy; Aneurysm; Instruments; System-on-a-chip; Valves; Transthoracic echocdrdiography; atrial septal aneurysm; diagnosis; transesophageal echocordioqraphy;
fLanguage
English
Publisher
ieee
Conference_Titel
Information Technology in Medicine and Education (ITME), 2012 International Symposium on
Conference_Location
Hokodate, Hokkaido
Print_ISBN
978-1-4673-2109-9
Type
conf
DOI
10.1109/ITiME.2012.6291346
Filename
6291346
Link To Document