Title
Study on electrical contact performance of circuit breaker terminals in the environment containing SO2
Author
Lu Jianguo ; Wang Jingqin ; Wang Lili ; Liu Lin ; Guan Ruiliang ; Yu Xiaofeng ; Zhao Sheng
Author_Institution
Hebei Univ. of Technol., Tianjin, China
fYear
2012
fDate
14-17 May 2012
Firstpage
50
Lastpage
54
Abstract
The test device of electrical contact performance of circuit breaker terminals is firstly developed in the paper, by which electrical contact performance of terminals can be automatically analyzed. Meanwhile, the electrical contact performance of circuit breaker terminals in the environment containing SO2 is studied by measuring the contact resistance of terminals in the conditions of different sulfur dioxide concentration within the same corrosion time and the same sulfur dioxide concentration within the different corrosion time.
Keywords
circuit breakers; contact resistance; electrical contacts; sulphur compounds; SO2; circuit breaker terminals; contact resistance; corrosion time; electrical contact performance; sulfur dioxide concentration; test device; circuit breaker; electrical contact performance; sulfur dioxide; terminals;