• DocumentCode
    569854
  • Title

    Optimal design and analysis system of AC solenoid valve

  • Author

    Xu Zhihong ; Lin Shuyi ; Cheng Zhuyuan

  • Author_Institution
    Sch. of Electr. Eng., Fuzhou Univ., Fuzhou, China
  • fYear
    2012
  • fDate
    14-17 May 2012
  • Firstpage
    134
  • Lastpage
    141
  • Abstract
    Solenoid Valve is a kind of typical low voltage electrical appliance with special working characteristic. Take FDF (FDF is a series of model of solenoid valve Sanhua company produces) series solenoid valve for example which applied widely in refrigerating system. Its temperature rise, vibration noise and so on are key points affecting the product quality. At present, the research on solenoid valve mostly specific to the field in system response time and structure design and it lacks the analysis on the overall performance indexes and optimal design. Therefore, the development of miniaturization, less consumption of the energy and the artificial intelligence of solenoid valve will be restrained. The simulation analyzing system for dynamic characteristic and temperature calculation in working state, dynamic characteristic analysis and integrated optimized design is built and it forms unique database of electrical appliance characteristic analysis and simulation design. It focuses on optimization design module in this paper. The changing regularity of the temperature rise of the electromagnetic mechanism is researched and concluded based on the 3D simulation in electromagnetic and temperature field. And the regular is brought into the optimization design of electromagnetic mechanism. Ant colony optimization is used in the optimal design for the overall performance index, and the dynamic process of the closing state and closed in long term working state are also considered at the same time. The design result is quite satisfied.
  • Keywords
    ant colony optimisation; electrical products; electromagnetic fields; product design; product quality; solenoids; temperature; valves; 3D simulation; AC solenoid valve; FDF series solenoid valve; ant colony optimization; artificial intelligence; dynamic characteristic analysis; electromagnetic mechanism; energy consumption; integrated optimized design; low voltage electrical appliance; miniaturization; optimization design module; product quality; refrigerating system; structure design; system response time; temperature field; vibration noise; optimal design; solenoid valve; temperature characteristic; the ant colony optimization;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Contacts (ICEC 2012), 26th International Conference on
  • Conference_Location
    Beijing
  • Electronic_ISBN
    978-1-84919-508-9
  • Type

    conf

  • DOI
    10.1049/cp.2012.0636
  • Filename
    6301881