DocumentCode :
570537
Title :
A study of three-phase APFC based on quadratic buck converter
Author :
Gao Xiaoqian
Author_Institution :
Sch. of Electr. & Electron. Eng., North China Electr. Power Univ., Beijing, China
fYear :
2012
fDate :
21-24 May 2012
Firstpage :
1
Lastpage :
4
Abstract :
This paper studies a new three-phase active power factor correction (APFC) Circuit based on quadratic buck converter, which can achieve high power factor and extensive step-down ratio. The operation principle of the three-phase quadratic buck APFC circuit was detailed analyzed. Then, the derivation of the equation for unity power factor of the circuit was given. Finally, this three-phase quadratic buck APFC circuit was simulated using MATLAB/Simulink. The results show that the power factor is high to 0.999 and the total harmonic distortion (THD) is low to 3% of the proposed APFC converter.
Keywords :
harmonic distortion; power convertors; power factor correction; APFC; MATLAB-Simulink; THD; operation principle; quadratic buck converter; step-down ratio; three-phase active power factor correction circuit; total harmonic distortion; unity power factor; Capacitors; Inductors; Integrated circuit modeling; Mathematical model; Power harmonic filters; Reactive power; Switches; high conversion ratio; power factor; quadratic buck converter; three-phase APFC circuit;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Innovative Smart Grid Technologies - Asia (ISGT Asia), 2012 IEEE
Conference_Location :
Tianjin
Print_ISBN :
978-1-4673-1221-9
Type :
conf
DOI :
10.1109/ISGT-Asia.2012.6303364
Filename :
6303364
Link To Document :