DocumentCode :
571987
Title :
POS use efficiency in multimodule accelerator with self-magnetic insulation
Author :
Zajivikhin, V.V.
Author_Institution :
TRINITI, Troitsk, Russia
Volume :
1
fYear :
1992
fDate :
25-29 May 1992
Firstpage :
592
Lastpage :
597
Abstract :
The top value of power enhancement and voltage multiplication in inductive store system with the plasma opening switch (POS) have been studied. Different kinds of loads have been considered. It has been shown that electron losses in vacuum transmission line (VTL) with self-magnetic insulation (SMI) can essentialy change the output pulse parameters. Among issues examined are also the effects of the POS on synchronization condition of the multimodule generator and on the optimum liner parameters used at Angara-5 facility.
Keywords :
electron accelerators; plasma switches; transmission lines; Angara-5 facility; POS use efficiency; SMI; VTL; electron losses; inductive storage system; multimodule accelerator; multimodule generator; optimum liner parameters; output pulse parameters; plasma opening switch; power enhancement; self magnetic insulation; vacuum transmission line; voltage multiplication; Generators; Impedance; Inductance; Leakage current; Load modeling; Mathematical model; Switches;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
High-Power Particle Beams, 1992 9th International Conference on
Conference_Location :
Washington,DC
Print_ISBN :
000-0-0000-0000-0
Type :
conf
Filename :
6306543
Link To Document :
بازگشت