Title :
Nanosecond breakdown of liquid dielectrics
Author :
Mankowski, J. ; Kristiansen, M. ; Hatfield, L.
Author_Institution :
Texas Tech University, Pulsed Power Laboratory, Department of Electrical Engineering, Lubbock, 79409-3102, USA
Abstract :
Breakdown characteristics of various liquids are investigated. Electric field strengths recorded are over 4 MV/cm and at breakdown times ranging from 1 to 4 nanoseconds. Liquids examined are filtered and unfiltered transformer oil, castor oil, and freon 12.
Conference_Titel :
High-Power Particle Beams, 1996 11th International Conference on
Conference_Location :
Prague, Czech Republic
Print_ISBN :
978-80-902250-3-9