• DocumentCode
    572697
  • Title

    Diagnostics of low energy carbon fibre Z-pinch

  • Author

    Kubes, Pavel ; Kravarik, Jozef ; Sldadnik-Sadowska, E. ; Baranowski, Jerzy ; Paduch, Marian ; Tomaszewski, K. ; Gogolewski, P.

  • Author_Institution
    FEE, Czech Techn. Univ., Technická 2, 16627 Prague 6, Czech Republic
  • Volume
    2
  • fYear
    1996
  • fDate
    10-14 June 1996
  • Firstpage
    737
  • Lastpage
    740
  • Abstract
    In this paper there are presented results of measurements of X-rays, fast electrons, ions. and schlieren pictures an exploding carbon fibre of 6µm in diameter, located between tips of the conical electrodes within a small 0.5 kJ Z-pinch facility. Thin fibres are often used as the load in Z-pinch experiments due to high initial cylindrical symmetry for a simple source of X-ray emission from low- and high-energy facilities [1]. In our experiments a strongly asymmetric source of XUV radiation and relatively long X-ray emission was observed.
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    High-Power Particle Beams, 1996 11th International Conference on
  • Conference_Location
    Prague, Czech Republic
  • Print_ISBN
    978-80-902250-3-9
  • Type

    conf

  • Filename
    6308439