DocumentCode :
573111
Title :
Eddy Current and Structure Optimization of High Frequency Coaxial Transformers Using the Numerical Computation Method
Author :
Water, Wayne ; Lu, Junwei
fYear :
2012
fDate :
19-21 June 2012
Firstpage :
1
Lastpage :
4
Abstract :
This paper introduces a High Frequency (100 to 300 kHz) Coaxial Transformer (HFCT) with >99% power efficiency accompanied by an optimization work of its geometrical structure. The optimization work is undertaken using Finite Element Method (FEM) based numerical technique in a 2-dimension structure. An eddy current analysis has also been conducted to determine the wire dimension and configuration for the designed 8 kW HFCT. The structural optimization work is focused on the relationship between the winding distance and parameters of the leakage inductance (Leq) and the coupling capacitance (Cps) of the HFCT. Furthermore, a trade-off point is found for the 8 kW HFCT based on the calculation result of Leq and Cps.
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Field Problems and Applications (ICEF), 2012 Sixth International Conference on
Conference_Location :
Dalian, Liaoning, China
Print_ISBN :
978-1-4673-1333-9
Type :
conf
DOI :
10.1109/ICEF.2012.6310326
Filename :
6310326
Link To Document :
بازگشت