Title :
Interpolation missing cone of conical reconstruction with iterative phase retrieval algorithm
Author :
Hommi, Motonobu ; Kikuchi, Kazuo ; Tanaka, Toshiyuki
Author_Institution :
Sch. of Sci. & Technol., Keio Univ., Tokyo, Japan
Abstract :
We previously implemented a conical CT system as X-ray CT system for industrial inspection. But there is the problem, “missing cone” problem, which conical data is missed in fourier space, and vertical accuracy was comparatively low. We intend to improve the vertical accuracy by iterative phase retrieval algorithm. The overall reconstruction algorithm is based on Filtered back projection algorithm and Iterative Phase Retrieval algorithm. We implemented this simulation with the Shepp-Logan phantom, which is often used for CT simulation. Through the study it was revealed that the proposed method can recovery missing data of low frequency.
Keywords :
Fourier analysis; computerised tomography; filtering theory; image retrieval; interpolation; iterative methods; Filtered back projection algorithm; Fourier space; Shepp-Logan phantom; X-ray CT system; conical CT system; conical reconstruction; industrial inspection; interpolation missing cone; iterative phase retrieval algorithm; vertical accuracy; FBP algorithm; Iterative phase retrieval algorithm; Missing cone; Oblique CT; Xray computed tomography;
Conference_Titel :
SICE Annual Conference (SICE), 2012 Proceedings of
Conference_Location :
Akita
Print_ISBN :
978-1-4673-2259-1