• DocumentCode
    576338
  • Title

    Influences on image quality of filter installation errors for airborne multi-spectral camera

  • Author

    Zhang, Xuguo ; Zhu, Dakai ; Wang, Li ; Lin, Zhaorong

  • Author_Institution
    Beijing Inst. of Space Mech. & Electr., Beijing, China
  • fYear
    2012
  • fDate
    22-27 July 2012
  • Firstpage
    4217
  • Lastpage
    4220
  • Abstract
    In this paper, influences of filter installation errors on image quality are studied for airborne multispectral imager. The results show that focus length changes has little influence on image quality, and focus movements caused by filter installation errors have bigger influence on image quality and resolution. In order to get better images, filters should be installed carefully, and keep them parallel with the image plane. Influences of mechanical vibration on filter distortion should be avoided as well.
  • Keywords
    CMOS image sensors; filtering theory; image resolution; space vehicles; spectral analysis; airborne multispectral imager; filter installation error; focus movement; image quality; image resolution; Adaptive optics; Image quality; Multispectral imaging; Optical filters; Optical imaging; Optical sensors;