Title :
Determination of Equivalent Inductance of Current Shunts at Frequency Up to 200 kHz
Author :
Jiangtao Zhang ; Xianlin Pan ; Wenfang Liu ; Yang Gu ; Biao Wang ; Deshi Zhang
Author_Institution :
Jilin Univ., Changchun, China
Abstract :
We report on the measurement techniques and results of the equivalent inductance of current shunts at frequencies from 50 to 200 kHz. With a three-branch binary inductive current divider and difference detection transformer, the equivalent inductance of the cagelike shunts was measured against a set of four-terminal resistors whose time constants were accurately determined. The verification experiments for the systematic errors of the measurement setup and the phase comparator with the current ratio of 2:1 are also presented.
Keywords :
current transformers; inductance measurement; measurement errors; resistors; voltage dividers; binary inductive current divider; cagelike shunt; current shunt; difference detection transformer; equivalent inductance measurement; frequency 50 kHz to 200 kHz; phase comparator; resistor; systematic measurement error; Current measurement; Electrical resistance measurement; Inductance; Inductance measurement; Shunts (electrical); Standards; Voltage measurement; Binary inductive current divider (BICD); current shunts; difference detection transformer (DDT); equivalent inductance; phase angle errors;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
DOI :
10.1109/TIM.2013.2241136